Art.nr: 8532052

Grease sensor GA-SG1 5 m cable

432,86 

labkotec

Monitors the grease level in a grease trap is full and monitors leakage.

Fits Labcotek GA-1 & GA-2 grease trap alarms

RSK-No 5622399
ArtNr 8532052

– Protects our environment
– Versatile device for basic requirements
– According to EN 1825 and DIN 4040 standards
– Suitable for all grease traps
– Can be connected to remote monitoring systems

Connection: Hanging in its cable 5m (max 200 m cable)+

Control units GA-1 and GA-2
Dimensions: 125 mm x 75 mm x 35 mm (L x H x W)
Material: Polycarbonate
Enclosure: IP65
Operating temperature: -30 °C…+50 °C
Supply voltage: 230 VAC ± 10 %, 50/60 Hz
The unit has no switch.
Power consumption: 5 VA
Sensors: 1 or 2 GA-SG1 sensors
Relay outputs: Potential-free relay output 250 V, 5 A
1 for GA-1 Operating delay 10 seconds.
2 for GA-2 Relay de-energizes when disconnected.
Electrical safety: IEC/EN 61010-1, Class II , CAT II
EMC: IEC/EN 61000-6-3 (Emission)
IEC/EN 61000-6-1 (Immunity)

Product details

Article number: 8532052
Brand: Labkotec

Do you have questions?

Contact us and we will help you!

010 490 10 50 info@avloppscenter.se
Avskiljar Larm IdOil 20-30 OMS-1 GA-1-2 SWE 4 2018
GA-1 GA-2 SWE 10 2014 Net
GA2 Manual Swe D15623Br

Monitors the grease level in a grease trap is full and monitors leakage.

Fits Labcotek GA-1 & GA-2 grease trap alarms

RSK-No 5622399
ArtNr 8532052

– Protects our environment
– Versatile device for basic requirements
– According to EN 1825 and DIN 4040 standards
– Suitable for all grease traps
– Can be connected to remote monitoring systems

Connection: Hanging in its cable 5m (max 200 m cable)+

Control units GA-1 and GA-2
Dimensions: 125 mm x 75 mm x 35 mm (L x H x W)
Material: Polycarbonate
Enclosure: IP65
Operating temperature: -30 °C…+50 °C
Supply voltage: 230 VAC ± 10 %, 50/60 Hz
The unit has no switch.
Power consumption: 5 VA
Sensors: 1 or 2 GA-SG1 sensors
Relay outputs: Potential-free relay output 250 V, 5 A
1 for GA-1 Operating delay 10 seconds.
2 for GA-2 Relay de-energizes when disconnected.
Electrical safety: IEC/EN 61010-1, Class II , CAT II
EMC: IEC/EN 61000-6-3 (Emission)
IEC/EN 61000-6-1 (Immunity)

Article number: 8532052
Brand: Labkotec

Do you have questions?

Contact us and we will help you!

010 490 10 50 info@avloppscenter.se