AC flow-controlled phosphorus trap XL+ double pump, pick-up price

6.899,54 

Shipping will be added

A solution for multiple properties, contact us for help with sizing

A flow-controlled phosphorus trap that doses the right amount of chemistry depending on water use in the house.
You avoid the corrosive indoor chemical spray found in simpler solutions.

The phosphorus trap is placed between the sludge separator and the infiltration, in addition to which you get a pumping solution from the sludge separator to the bed, which extends the life of the bed and the degree of purification.

To succeed in capturing phosphorus with chemistry, the following is required.
The flocculant reacts with water and only seconds later it is ineffective. As the time is very short, phosphorus in toilet water must be met with the flocculant within 10 seconds for optimal reduction.

For the meeting between the phosphorus and the flocculant to be effective within the active time, movement is required, which takes place with a return pumping of outgoing sludge separated water together with the chemistry.

No risk of mis-dosing thanks to flow-controlled pumping.
Overdosing can result in sludge escape in the separator which clogs the infiltration. Underdosing results in no reduction of phosphorus.

Through customized dosing of flocculants, you get your plant to meet high phosphorus levels. There is no need to manually adjust the dosage after changes in the household or when leaving the house for vacation as needed on other simple chemical pumping systems.

Alarm
Alarms indicate when it is time to add new chemistry.

Easy to use
No adjustment of dosage due to changing number of people in the household or unplugging when leaving home. Everything is done automatically all the time.

Benefits and advantages
– Proper flow-controlled dosing
– Can handle highly variable loads
– Easy to install
– Never overdose
– Easy and safe to use
– Installed outdoors, no corrosive chemistry indoors
– Alerts when flocculant needs to be replenished
– Infiltration pump solution for better lifetime and function

The pump well is placed between the sludge separator and the infiltration.
The technical well is placed near the pump well, in it there are electrical cabinets, chemical pump and chemical canister to ensure a good environment.
The wastewater flows by gravity to the pump well.
All the water is pumped out from the pumping well and in this way the right volume of chemical is obtained to be dosed to the sludge separator.
Approximately 10% of the pumped water is returned to the sludge separator to create movement of the water in the sludge separator so that the chemistry can be mixed effectively

Buy to chemistry PAX XL 60

You should not compromise on the size of the sludge separator, the hydraulic properties when using chemistry become much more difficult for the sludge separator so you must get a slower flow otherwise the risk of sludge escape is great.
It does not help to have several emptyings, but the size should be double the normal.

Product details

Article number: xylQ-8504

Do you have questions?

Contact us and we will help you!

010 490 10 50 info@avloppscenter.se
Vilken Fosforfalla Ska Jag Valja

Shipping will be added

A solution for multiple properties, contact us for help with sizing

A flow-controlled phosphorus trap that doses the right amount of chemistry depending on water use in the house.
You avoid the corrosive indoor chemical spray found in simpler solutions.

The phosphorus trap is placed between the sludge separator and the infiltration, in addition to which you get a pumping solution from the sludge separator to the bed, which extends the life of the bed and the degree of purification.

To succeed in capturing phosphorus with chemistry, the following is required.
The flocculant reacts with water and only seconds later it is ineffective. As the time is very short, phosphorus in toilet water must be met with the flocculant within 10 seconds for optimal reduction.

For the meeting between the phosphorus and the flocculant to be effective within the active time, movement is required, which takes place with a return pumping of outgoing sludge separated water together with the chemistry.

No risk of mis-dosing thanks to flow-controlled pumping.
Overdosing can result in sludge escape in the separator which clogs the infiltration. Underdosing results in no reduction of phosphorus.

Through customized dosing of flocculants, you get your plant to meet high phosphorus levels. There is no need to manually adjust the dosage after changes in the household or when leaving the house for vacation as needed on other simple chemical pumping systems.

Alarm
Alarms indicate when it is time to add new chemistry.

Easy to use
No adjustment of dosage due to changing number of people in the household or unplugging when leaving home. Everything is done automatically all the time.

Benefits and advantages
– Proper flow-controlled dosing
– Can handle highly variable loads
– Easy to install
– Never overdose
– Easy and safe to use
– Installed outdoors, no corrosive chemistry indoors
– Alerts when flocculant needs to be replenished
– Infiltration pump solution for better lifetime and function

The pump well is placed between the sludge separator and the infiltration.
The technical well is placed near the pump well, in it there are electrical cabinets, chemical pump and chemical canister to ensure a good environment.
The wastewater flows by gravity to the pump well.
All the water is pumped out from the pumping well and in this way the right volume of chemical is obtained to be dosed to the sludge separator.
Approximately 10% of the pumped water is returned to the sludge separator to create movement of the water in the sludge separator so that the chemistry can be mixed effectively

Buy to chemistry PAX XL 60

You should not compromise on the size of the sludge separator, the hydraulic properties when using chemistry become much more difficult for the sludge separator so you must get a slower flow otherwise the risk of sludge escape is great.
It does not help to have several emptyings, but the size should be double the normal.

Article number: xylQ-8504

Do you have questions?

Contact us and we will help you!