Art.nr: bag6008565

Baga Level rocker with weight, single or double acting

146,74 

Level rocker, standard with weight, single or double acting

Application
Level switch for start, stop or alarm.
Permitted for drinking, sewage and waste water.
The NV level switch is used for pumping stations or other installations where level control or alarm is required.

Cable length 9 meters

Description
The level rocker consists of a float and a weight.
The weight is adjustable, to get the desired distance between on and off. Inside the float a microswitch is placed.

As the liquid level rises, the weight hangs on and the float rises. A ball then falls against the microswitch which gives a signal.

The gold-plated contact surfaces of the microswitch provide a reliable signal even at low operating voltage and guarantee a long service life

The level rocker is suitable for BAGA automatic cabinets or other applications.

  • BLS Alarm cabinet
  • BN 1 Level control of 1 pump.
  • BN 2 Level control of 2 pumps.
  • BNT As emergency rocker for control with pressure sensor

    Technical data

  • Voltage max 250 V AC 50/60 Hz
  • Rated current max 5 AC 1 short circuit protection max 10A
  • Dimensions cable 9 m, float 120×70 mm
  • Protection class IP 68
  • Total weight 1.7 kg (cable, float and weight)

The rocker is used to accurately monitor high (normally open) or low (normally closed) liquid levels to activate pump control panels and alarms in water and wastewater applications.

Control differential of 4 cm above or below horizontal level

SPDT = three conductor cable with double level, can also be used with one level.

Normally open models (high level): The control switch turns on (closes) when the float tips slightly above horizontal signaling a high level and turns off (opens) when the float drops slightly below horizontal.

Normally closed models (low levels): The control switch turns on (closes) when the float tips slightly below horizontal, signaling a low level, and turns off (opens) when the float tips slightly above horizontal.

Features
Can be wired to operate in either normally open or normally closed applications
High impact, corrosion resistant, polypropylene floating housing
Control differential of 4 cm above or below the horizontal plane
Green colored cap for easy identification of SPDT control switch

For normally open (high level) or normally closed (low level) applications

Two mounting options for installation flexibility:
Mounting clamp: for applications where the float can be attached to a discharge pipe or similar mounting device
Externally weighted: for applications where the float can be suspended from above
UL listed, CSA certified
Five-year limited warranty

CABLES:
Flexible 18 gauge, 3 conductor (UL, CSA) SJOW, waterproof (CPE)

Rocker:
7.0 x 12.3 cm, corrosion resistance, polypropylene housing for use in drains and water up to 140°F (60°C)

MAXIMUM WATER DEPTH:
9 meters

ELECTRICAL:
5 amps, 125/250 VAC, 50/60 Hz

NOTE: This switch is not recommended for controlling electrical loads less than 100 milliamps, 12 VAC and non-arcing electrical loads.

Product details

Article number: bag6008565

Do you have questions?

Contact us and we will help you!

010 490 10 50 info@avloppscenter.se
Vippa Nv Datablad1
Vippor Injustering1

Level rocker, standard with weight, single or double acting

Application
Level switch for start, stop or alarm.
Permitted for drinking, sewage and waste water.
The NV level switch is used for pumping stations or other installations where level control or alarm is required.

Cable length 9 meters

Description
The level rocker consists of a float and a weight.
The weight is adjustable, to get the desired distance between on and off. Inside the float a microswitch is placed.

As the liquid level rises, the weight hangs on and the float rises. A ball then falls against the microswitch which gives a signal.

The gold-plated contact surfaces of the microswitch provide a reliable signal even at low operating voltage and guarantee a long service life

The level rocker is suitable for BAGA automatic cabinets or other applications.

  • BLS Alarm cabinet
  • BN 1 Level control of 1 pump.
  • BN 2 Level control of 2 pumps.
  • BNT As emergency rocker for control with pressure sensor

    Technical data

  • Voltage max 250 V AC 50/60 Hz
  • Rated current max 5 AC 1 short circuit protection max 10A
  • Dimensions cable 9 m, float 120×70 mm
  • Protection class IP 68
  • Total weight 1.7 kg (cable, float and weight)

The rocker is used to accurately monitor high (normally open) or low (normally closed) liquid levels to activate pump control panels and alarms in water and wastewater applications.

Control differential of 4 cm above or below horizontal level

SPDT = three conductor cable with double level, can also be used with one level.

Normally open models (high level): The control switch turns on (closes) when the float tips slightly above horizontal signaling a high level and turns off (opens) when the float drops slightly below horizontal.

Normally closed models (low levels): The control switch turns on (closes) when the float tips slightly below horizontal, signaling a low level, and turns off (opens) when the float tips slightly above horizontal.

Features
Can be wired to operate in either normally open or normally closed applications
High impact, corrosion resistant, polypropylene floating housing
Control differential of 4 cm above or below the horizontal plane
Green colored cap for easy identification of SPDT control switch

For normally open (high level) or normally closed (low level) applications

Two mounting options for installation flexibility:
Mounting clamp: for applications where the float can be attached to a discharge pipe or similar mounting device
Externally weighted: for applications where the float can be suspended from above
UL listed, CSA certified
Five-year limited warranty

CABLES:
Flexible 18 gauge, 3 conductor (UL, CSA) SJOW, waterproof (CPE)

Rocker:
7.0 x 12.3 cm, corrosion resistance, polypropylene housing for use in drains and water up to 140°F (60°C)

MAXIMUM WATER DEPTH:
9 meters

ELECTRICAL:
5 amps, 125/250 VAC, 50/60 Hz

NOTE: This switch is not recommended for controlling electrical loads less than 100 milliamps, 12 VAC and non-arcing electrical loads.