Art.nr: xylq-8745

Matala EZClear 25 Watt

367,43 

Matala EZClear UV-C Clarifiersare used to reduce harmful bacteria, parasites, fungi, protozoa and viruses and reduce blooms of floating green algae.

This is a simpler version than the regular Matala Spectrum which is stainless steel and has better reflection with its shiny surface and gets better values.
The EZClear model is prepared for hose connection and the Spectrum model is for thread connection.

Supplied with high-quality Philips lamps, these lamps are considered the best ultraviolet lamps in the world.
They are long lasting and provide maximum UV effect.
All UV lamps should be changed once a year.

  • 360° adjustment of hoses in multiple directions
  • Easy installation, no tools required
  • Hose fittings accept 3/4″, 1″, 1-1/4, 1-1/2″ ID hose
  • Transparent adapter connects to 1.5″ rigid Sch 40 PVC pipe
  • Translucent hose ends provide blue UV light monitoring
  • 15′ power cord with in-line transformer

All sizes of devices come with universal connectors that allow you to connect to 3/4″, 1″, 1.25″ or 1.5″ hose

For best results with UV water treatment, the water should be free of e.g. particles, iron, manganese, lime and surface water before the UV filter.
This is solved with water filters for the intended function.

  • Max. iron 0.3mg/l
  • Maximum hardness 120 mg/l
  • Max tannin 0,1 mg/l

Performance
Wastewater 300 J/m2: 1,458 l/h
Drinking water 400 J/m2: 1,095 l/h
Pool & fish ponds: 1,512 l/h
Max pool or pond size 4,000 liters

We recommend halving these figures for more difficult conditions on the water.

Size
Length: 656mm
Diameter: 51mm

Connection:
Connection suitable for 19 mm, 25 mm, 32 mm and 40 mm hose.

Features:
High quality lamp and quartz sleeve maintain a high output of 254

Philips UV lamp TUV 25T5 4P-SE
Main application disinfection
Lifetime (nom) 9000 hours
System description High efficiency TUV T5 lamps are single or double ended UVC (germicidal) lamps used in professional water and air disinfection units. TUV T5 lamps offer constant UV output throughout their lifetime for maximum disinfection safety and high system efficiency.

Technical info
Color code TUV
Color designation – [Not specified]
Power loss at useful life 15%

Connection: 4-pin single socket

PRE-TREATMENT

For optimal effect of the UV treatment in tube form, proper pretreatment is required. The recommended limit values below are a guide to the choice and possible need for pre-treatment of the water.

  • Iron (Fe) < 0,3 ppm (0,3 mg/l)
  • Hardness < 120 ppm (120 mg/l = 6,7°dH)
  • UVT10 > 75%
  • Total suspended solids (TSS) < 5 ppm (5 mg/l)

FOR PARTICLE FILTRATION, WE RECOMMEND A PRE-FILTER WITH 5 MICRON FILTRATION.

  • For smaller flows, use a cartridge filter with 5 my cartridge.
  • For larger flows, use a bag filter with 5 my filter bag.

HERE ARE SOME POINTS THAT SHOULD BE MET TO ACHIEVE THE OPTIMAL EFFECT OF UV TREATMENT:

  • Proper pre-treatment of incoming water if you do not have Aquatron UV
  • Right flow rate in relation to UV plant capacity
  • If the pump flow is too high in relation to the UV system, the flow should be throttled down
  • Cleaning the quartz glass 2-3 times a year (in some cases more often)
  • Changing the UV lamp in time

Product details

Article number: xylq-8745
Brand: Matala

Do you have questions?

Contact us and we will help you!

010 490 10 50 info@avloppscenter.se
Certification
TUV 25T5 4P-SE
Matala UV Instruction-SS UVC

Matala EZClear UV-C Clarifiersare used to reduce harmful bacteria, parasites, fungi, protozoa and viruses and reduce blooms of floating green algae.

This is a simpler version than the regular Matala Spectrum which is stainless steel and has better reflection with its shiny surface and gets better values.
The EZClear model is prepared for hose connection and the Spectrum model is for thread connection.

Supplied with high-quality Philips lamps, these lamps are considered the best ultraviolet lamps in the world.
They are long lasting and provide maximum UV effect.
All UV lamps should be changed once a year.

  • 360° adjustment of hoses in multiple directions
  • Easy installation, no tools required
  • Hose fittings accept 3/4″, 1″, 1-1/4, 1-1/2″ ID hose
  • Transparent adapter connects to 1.5″ rigid Sch 40 PVC pipe
  • Translucent hose ends provide blue UV light monitoring
  • 15′ power cord with in-line transformer

All sizes of devices come with universal connectors that allow you to connect to 3/4″, 1″, 1.25″ or 1.5″ hose

For best results with UV water treatment, the water should be free of e.g. particles, iron, manganese, lime and surface water before the UV filter.
This is solved with water filters for the intended function.

  • Max. iron 0.3mg/l
  • Maximum hardness 120 mg/l
  • Max tannin 0,1 mg/l

Performance
Wastewater 300 J/m2: 1,458 l/h
Drinking water 400 J/m2: 1,095 l/h
Pool & fish ponds: 1,512 l/h
Max pool or pond size 4,000 liters

We recommend halving these figures for more difficult conditions on the water.

Size
Length: 656mm
Diameter: 51mm

Connection:
Connection suitable for 19 mm, 25 mm, 32 mm and 40 mm hose.

Features:
High quality lamp and quartz sleeve maintain a high output of 254

Philips UV lamp TUV 25T5 4P-SE
Main application disinfection
Lifetime (nom) 9000 hours
System description High efficiency TUV T5 lamps are single or double ended UVC (germicidal) lamps used in professional water and air disinfection units. TUV T5 lamps offer constant UV output throughout their lifetime for maximum disinfection safety and high system efficiency.

Technical info
Color code TUV
Color designation – [Not specified]
Power loss at useful life 15%

Connection: 4-pin single socket

PRE-TREATMENT

For optimal effect of the UV treatment in tube form, proper pretreatment is required. The recommended limit values below are a guide to the choice and possible need for pre-treatment of the water.

  • Iron (Fe) < 0,3 ppm (0,3 mg/l)
  • Hardness < 120 ppm (120 mg/l = 6,7°dH)
  • UVT10 > 75%
  • Total suspended solids (TSS) < 5 ppm (5 mg/l)

FOR PARTICLE FILTRATION, WE RECOMMEND A PRE-FILTER WITH 5 MICRON FILTRATION.

  • For smaller flows, use a cartridge filter with 5 my cartridge.
  • For larger flows, use a bag filter with 5 my filter bag.

HERE ARE SOME POINTS THAT SHOULD BE MET TO ACHIEVE THE OPTIMAL EFFECT OF UV TREATMENT:

  • Proper pre-treatment of incoming water if you do not have Aquatron UV
  • Right flow rate in relation to UV plant capacity
  • If the pump flow is too high in relation to the UV system, the flow should be throttled down
  • Cleaning the quartz glass 2-3 times a year (in some cases more often)
  • Changing the UV lamp in time
Article number: xylq-8745
Brand: Matala

Do you have questions?

Contact us and we will help you!

010 490 10 50 info@avloppscenter.se